Horizontal Airflow Direction Auto-Control
•
• •
•
When set a Airflow Direction Auto-Control with remote
control, the vanes swings left and right as shown in the
diagram.
•
• •
•
The vanes does not swing when the Indoor Fan Motor stops
during operation at 22° angle.
•
• •
•
When stopped with remote control, the discharge vent is
reset, and stopped at the reset position.
•
• •
•
During Anti-dew condensation prevention, Airflow Direction
Auto-control angle change from 0° - 44° to 14° - 30° under
Cooling and Soft Dry operation mode.
Horizontal Airflow Direction manual Control
•
• •
•
When the manual Airflow Direction Selection Button is
pressed, the automatic airflow is released and the airflow
direction vane move left and right in the range shown in the
diagram.
The louver can be adjusted by pressing the button to the
desired vane position.
1. There is no swinging while indoor fan motor is stopped during Cooling, Ion and Soft Dry operation.
2. In Heating operation, when the piping air temperature reaches 38°C, the airflow direction is Auto Swing left and right (8°-36°). When the
piping air temperature falls to 35°C, the airflow direction is stop at 22° angle.
•
• •
•
When the remote control is used to stop the operation, the vanes is reset, and stopped at reset position.
•
• •
•
During Anti-dew condensation prevention, Airflow Direction Manual control angle change from 0°, 11°, 22°, 33°, 44° to 14°, 18°,
22°, 26°, 30° under Cooling and Soft Dry operation mode.
8.8. Delay ON Timer Control
•
• •
•
When the Delayed ON Timer is set by using the remote control, the unit will start operate slightly before the set time, so that
the room will reach nearly to the set temperature by the desired time.
•
• •
•
For Cooling and Soft Dry mode, the operation will start 15 minutes before the set time.
•
• •
•
For Heating mode, the operation will start 30 minutes before the set time.
•
• •
•
For Automatic mode, the indoor fan will operate at SLo speed for 25 seconds, 30 minutes before the set time to detect the
intake air temperature to determine the operation mode. The operation indication lamp will blink at this time.
8.9. Remote Control Signal Receiving Sound
•
• •
•
Long beep sound will be heard when:-
−
− −
−
Stopping the Air Conditioner using ON/OFF switch.
−
− −
−
Stopping the Quiet Mode.
−
− −
−
Stopping the Powerful Mode.
−
− −
−
Stopping the Ion Mode.
•
• •
•
Short beep sound will be heard for others.
•
• •
•
To switch off the beep sound:-
Press the “Automatic Operation Button” continuously for 10 seconds or more (“beep” “beep” will be heard at the 10th second).
Repeat the above if you want to switch ON the beep sound.
However, if the “Automatic Operation Button” has been pressed the Automatic operation will be activated.
If you do not require this operation, you may change it by using the remote control.
29