Page #4 background imageLoading...
Page #4 background image
Indoor Unit
Ionizer Control
Ionizer control for generate negative ion
in discharge air.
Indoor Fan Speed Control
High, Medium and Low.
Automatic Fan Speed Mode
Heating : Fan speed varies from Me
SSLo in accordance with
indoor heat exchanger.
Cooling : Fan rotates at Hi, Me and
Lo- speed. Deodorizing
control is available.
Soft Dry : Fan rotates at Lo- speed.
Deodorizing control is
available.
Automatic air swing and manual adjusted
by remote control for vertical and horizontal
airflow.
Airflow Direction Control
Automatic Operation Button
Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
Press continuously for 5s or < 10s to
operate Test Run/Pump down. “Beep”
sound will be heard at the 5th second.
(Used when test running or servicing.)
Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. “Beep, beep” sound will
be heard at the 10th second.
AUTO
OFF / ON
Operation Indication Lamps (LED)
POWER (Green).......... Lights up in operation,
blinks in Automatic
Operation Mode judging
and Hot Start operation.
QUIET (Orange) ......... Lights up in Quiet Mode
Operation.
TIMER (Orange) .........
Lights up in Timer Setting.
POWERFUL (Orange) ... Lights up in Powerful
Mode Operation.
ION (Green) ...... Lights up in Ionizer
Mode Operation.
Operation Mode
Heating, Cooling, Soft Dry and Automatic
Mode.
Powerful Operation
Reaches the desired room temperature quickly.
Time Delay Safety Control
Restarting is inhibited for appro. 3 minutes.
Quiet Operation
To provide quiet operation.
7 Minutes Time Save Control
Cooling Operation only.
Anti-Dew Formation Control
Anti-Dew Formation Control for indoor unit
discharge area.
Random Auto Restart Control
Operation is restarted randomly after
power failure at previous setting mode.
Anti-Freezing Control
Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Hot-Start Control
At Heating Operation the indoor fan will
operate at SLo speed when indoor heat
exchanger temperature reaches 30°C.
Anti Cold Draft Control
The indoor fan operates at Lo
(30 sec.)
after that SSLo when the indoor heat
exchanger temperature is low.
(During Heating mode thermal off)
4
CS-W18CKE CU-W18CKE / CS-W24CKE CU-W24CKE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-W18CKE and is the answer not in the manual?

Panasonic CS-W18CKE Specifications

General IconGeneral
BrandPanasonic
ModelCS-W18CKE
CategoryAir Conditioner
LanguageEnglish

Related product manuals