3. Specifications
Model
Indoor CS-XZ20XKEW-H
Outdoor CU-Z20XKE
Performance Test Condition EUROVENT
Power Supply
Phase, Hz Single, 50
V 230
Min. Mid. Max.
Cooling
Capacity
kW 0.75 2.05 2.65
BTU/h 2560 6990 9040
kcal/h 650 1760 2280
Running Current A - 2.15 -
Input Power W 160 450 670
Annual Consumption kWh - 225 -
EER CLASS - A -
EER
W/W 4.69 4.56 3.96
BTU/hW 16.00 15.53 13.49
kcal/hW 4.06 3.91 3.40
ErP
Pdesign kW 2.1
SEER (W/W) 8.1
Annual Consumption kWh 91
Class A++
Power Factor % - 91 -
Indoor Noise (H / L / QLo)
Sound Pressure Level
dB(A)
37 / 24 / 19 (Single)
39 / 26 / - (Multi)
Sound Power Level dB(A) 53 / - / -
Outdoor Noise (H / L / QLo)
Sound Pressure Level
dB(A)
45 / - / -
Sound Power Level dB(A) 60 / - / -
Heating
Capacity
kW 0.75 2.80 4.00
BTU/h 2560 9550 13600
kcal/h 650 2410 3440
Running Current A - 2.80 -
Input Power W 160 620 940
COP CLASS - A -
COP
W/W 4.69 4.52 4.26
BTU/hW 16.00 15.40 14.47
kcal/hW 4.06 3.89 3.66
ErP
Pdesign kW 2.1
Tbivalent °C -10
SCOP (W/W) 4.8
Annual Consumption kWh 613
Class A++
Power Factor % - 96 -
Indoor Noise (H / L / QLo)
Sound Pressure Level
dB(A)
38 / 25 / 19 (Single)
40 / 27 / - (Multi)
Sound Power Level dB(A) 54 / - / -
Outdoor Noise (H / L / QLo)
Sound Pressure Level
dB(A)
46 / - / -
Sound Power Level dB(A) 61 / - / -
LOW Temp: Capacity (kW) / I. Power (W) / COP 2.90 / 830 / 3.49
EXTR LOW Temp: Capacity (kW) / I. Power (W) / COP 2.38 / 840 / 2.83
Max Current (A) / Max Input Power (W) 4.1 / 940