160
21.3 Piping Length Correction Factor
The characteristic of the unit has to be corrected in accordance with the piping length.
Note: The graphs show the factor after added right amount of additional refrigerant.
Cooling Capacity
3
1.0119
5
1.0000
7
0.9792
10
0.9650
15
0.9429
Heating Capacity
3
1.0261
5
1.0000
7
0.9687
10
0.9465
15
0.9237
Cooling Capacity
Correction Factor
Pipe Length (m)
2345678910111213141516
0.92
0.94
0.96
0.98
1.00
1.02
Heating Capacity
Correction Factor
Pipe Length (m)
2345678910111213141516
0.90
0.92
0.94
0.96
0.98
1.00
1.02
1.04