21.2 Heat Mode Outdoor Air Temperature Characteristic
Condition
- Indoor room temperature: 20°C Dry Bulb/ -°C Wet Bulb
- Unit setting: Standard piping length, forced heating at 30°C, Hi fan
- Compressor frequency: Rated for Heating operation
- Piping length: 5m
- Voltage: 230V
21.2.1 CS-XZ20XKEW-H CU-Z20XKE
Indoor Discharge
Air Temperature (°C)
Outdoor Air Temperature (°C)
High Pressure (MPa)
Outdoor Air Temperature (°C)
Current (A)
Outdoor Air Temperature (°C)
0.50
1.00
1.50
2.00
2.50
3.00
15
20
25
30
35
40
-20 -15 -10 -5 0 5 10 15
-20 -15 -10 -5 0 5 10 15
-20 -15 -10 -5 0 5 10 15
1.00
1.50
2.00
2.50
3.00
3.50
4.00