Operation mode
It is possible to operate the indoor units individually or simultaneously. The priority of
operation is placed on the first unit that turned on.
During operation, HEAT and COOL modes cannot activate at the same time for different
indoor units.
The power indicator blinks to indicate the indoor unit is standing by for different operation
mode.
AUTO : For your convenience.
Single
Unit selects operation mode every 10 minutes according to the setting and room
temperatures.
Multi
Unit selects operation mode every 3 hours according to setting temperature,
outdoor temperature and room temperature.
HEAT : Unit takes a while to warm up.
COOL : Provides efficient comfort cooling to suit your needs.
DRY : Unit operates at low fan speed to give a gentle cooling operation.
Energy saving temperature setting
Operating the unit within the recommended temperature range may save energy.
HEAT : 20 °C ~ 24 °C /
68 °F ~ 75 °F.
COOL: 26 °C ~ 28 °C /
79 °F ~ 82 °F.
Operating conditions
Use this air conditioner under the following temperature range.
Temperature °C (°F)
Indoor unit Outdoor unit
DBT WBT DBT WBT
COOL
Max. 32 (89.6) 23 (73.4) 46 (114.8) 26 (78.8)
Min. 16 (60.8) 11 (51.8) -10 (14.0) -
HEAT
Max. 30 (86.0) - 24 (75.2) 18 (64.4)
Min. 16 (60.8) - -15 (5.0) -16 (3.2)
DBT: Dry bulb temperature, WBT: Wet bulb temperature