100
14.10 Auto Restart Control
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be
selected randomly) after power supply resumes.
This type of control is not applicable during ON/OFF Timer setting.
This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.
14.11 Indication Panel
LED POWER TIMER iAUTO-X nanoe
TM
X ECO
Color Green Orange Orange Blue Orange
Light ON Operation ON Timer Setting ON iAUTO-X Mode ON nanoe
TM
X ON ECO ON
Light OFF Operation OFF Timer Setting OFF iAUTO-X Mode OFF nanoe
TM
X OFF ECO OFF
Note:
If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation
mode judgment, or ON timer sampling.
If Timer LED is blinking, there is an abnormality operation occurs.
14.12 nanoe
TM
X Operation
Generate nanoe
TM
X (water wrapped ion particle) to moisturize skin, provide deodorization & sterilization effect.
nanoe
TM
X operation start condition
o During unit running at any operation mode, if nanoe
TM
X operation is activated, combination operation
(operation mode + nanoe
TM
X operation) starts.
o During unit is OFF, if nanoe
TM
X operation is activated, nanoe
TM
X individual operation starts.
nanoe
TM
X operation stop condition
o When OFF/ON button is pressed to stop the operation.
o When nanoe
TM
X button is pressed.
o When OFF Timer activates.
nanoe
TM
X operation pause condition
o When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe
TM
X operation resume after
indoor fan restarts.
o When indoor intake temperature 35°C and 5°C. nanoe
TM
X operation resume after indoor intake
temperature < 35°C or 5°C continuously for 6 minutes.
Indoor fan control
o During any operation mode combines with nanoe
TM
X operation, fan speed follows respective operation
mode. However, nanoe
TM
X system enabled when fan speed 360 rpm to ensure proper negative ion
distribution, nanoe
TM
X system disabled when fan speed < 360 rpm.
o During nanoe
TM
X individual operation, fan speed follow remote control setting. Auto Fan Speed for
nanoe
TM
X individual operation is cooling medium fan. Powerful & Quiet is disabled during nanoe
TM
X.
Airflow direction control
o During any operation mode combines with nanoe
TM
X operation, airflow direction follows respective operation
mode.
o During nanoe
TM
X individual operation, Air Swing follow remote control setting.
Timer control
o When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe
TM
X
operation status.
o When ON Timer activates during any operation, no change on current operation.
o When OFF Timer activates during any operation, all operation stops and the latest nanoe
TM
X operation
status is saved.
Indicator
o When nanoe
TM