2. Ionising Operation Stop Condition
When one of the following condition is satisfied, ION operation
stops.
A. Stopped by ON/OFF switch.
B. Timer OFF activates.
C. ION operation button is pressed again.
D. ION feedback signal shows error.
3. Ionizer operation status is not memorised by micon. After OFF,
when operation is ON again, air conditioner operates without
ionizer operation.
c. Timer during ionizer operation
Refer to case study in next page for detail.
8.1.18.1. Ionizer Problem Detection Control
i. Purpose
To inform user of ionizer problems and detection.
ii. Two types of problem detection control:
Control Detection Method Protection
Recovery
ERROR
PROTECTION
(i)
Actual ion: ON
(i)
Actual ion ON for 10s &
OFF for 30 min.
continuously for 24 times
(approx. 11 hr. 30 min.)
(i) Actual ion is permanently
OFF & ion LED is blinking.
(i)Press ON/
OFF
button to
OFF
(ii)
ion feedback
signal: 0V
(ii)
Within 24 counts, if
anytime CONDITION
becomes false then
count is cleared.
(ii)
Press remote control ion
button for
a) ON: Ion LED blink & buzzer
= beep
b) OFF: Ion LED OFF &
buzzer = beep
(ii)
(iii)
Reset
power
Off by
force
operation
BREAKDOWN
PROTECTION

Related product manuals