EasyManua.ls Logo

Panasonic CU-E18CKR - Page 39

Panasonic CU-E18CKR
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
the following operation.
1. During remote control setting is less than 28 deg
Indoor Fan Speed
Above Hi minHz = 21
Above Me- minHz = 21
Less than Me- minHz = 18
Auto minHz = 16
2. During Powerful ON
minHz = 22
However, when less than thermo OFF for 120 sec. continuously,
the above control will be cancel.
- During heating operation, operate the followings control.
1. During Remote Control setting is less than 18 deg
Indoor Fan Speed
Above Hi minHz = 30
Above Lo minHz = 25
Less than Lo minHz = 15
2. During Powerful ON
minHz = 35
However, when less than thermo OFF for 100 sec. continuously,
the above control will be cancel.
8.2.2. Protection Control For Cooling & Soft Dry Operation
8.2.2.1. Outdoor Air Temperature Control
The compressor operating frequency is regulated in accordance to the outdoor air temperature
as shown in the diagram below.