the following operation.
1. During remote control setting is less than 28 deg
Indoor Fan Speed
Above Hi minHz = 21
Above Me- minHz = 21
Less than Me- minHz = 18
Auto minHz = 16
2. During Powerful ON
minHz = 22
However, when less than thermo OFF for 120 sec. continuously,
the above control will be cancel.
- During heating operation, operate the followings control.
1. During Remote Control setting is less than 18 deg
Indoor Fan Speed
Above Hi minHz = 30
Above Lo minHz = 25
Less than Lo minHz = 15
2. During Powerful ON
minHz = 35
However, when less than thermo OFF for 100 sec. continuously,
the above control will be cancel.
8.2.2. Protection Control For Cooling & Soft Dry Operation
8.2.2.1. Outdoor Air Temperature Control
The compressor operating frequency is regulated in accordance to the outdoor air temperature
as shown in the diagram below.