– 22 –
MAC9702008C2
CS-MC90KE
Operation Details
2) Soft Dry Mode Operation
• The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote
Control, and then Soft Dry operation will start.
• During Soft Dry operation, the Indoor Fan will operate and stop at 4-second intervals at low speed.
• The operation will be switched on and off for up to 10 minutes “ON” and 6 minutes “OFF”. Once Soft Dry opera-
tion is turned off, it stops for 6 minutes.
• Once the compressor stops, it will not start for 3 minutes during Cooling operation.
• Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during
compressor stops.)
• Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (Refer page 22)
When Automatic Fan Speed is selected at Remote Control during Soft Dry Operation.
• Fan speed rotates at SLo and Lo speed.
• Deodorizing Control.
* SLo: Indoor Fan rotates at 4-second intervals at low speed.
Time Delay Safety Control
Anti-Freezing Control
Compressor Reverse Rotation
Protection
Automatic Fan Speed Mode
Indoor
Fan
COMP
stop stop
stop
SLo Lo SLo
ON ON
OFF
40" 40"6'
Untitled-24 6/25/00, 5:31 PM22