Panasonic CU-MC180KE - Outdoor Unit Functions

Panasonic CU-MC180KE
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 4 –
MAC9702008C2
CS-MC90KE
Outdoor Unit
Functions
Compressor Reverse Rotation
Protection Control
Restart Control
(3 minutes)
Once the compressor stops, the compressor
and the outdoor fan motor will not start for 3
minutes.
(Fan motor is still running if the compressor is
stopped by overload protector tripping.)
Overload Protector
Starting Current Control
(2 seconds delay)
When both compressors are started
simultaneously, one compressor will start
immediately whereas another compressor
will start after 2 seconds.
To protect compressor from reverse rotation
when there is a instantaneous power failure.
Once the compressor is activated, it does not
stop for 60 secs. (Stops immediately with
remote control stop signal.)
60 secs. Forced Operation Control
Untitled-23 6/25/00, 5:30 PM4