EasyManua.ls Logo

Panasonic CU-RE28PKR - Troubleshooting Common Issues; Symptoms Not Indicating Malfunction; Checks Before Calling for Service; Non-Serviceable Criteria

Panasonic CU-RE28PKR
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Indoor CS-RE24PKR CS-RE28PKR
Model
Outdoor CU-RE24PKR CU-RE28PKR
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 15.88 (5/8) 6.35 (1/4) / 15.88 (5/8)
Standard length m (ft) 5.0 (16.4) 5.0 (16.4)
Length range (min – max) m (ft) 3 (9.8) ~ 30 (98.4) 3 (9.8) ~ 30 (98.4)
I/D & O/D Height Different m (ft) 20 (65.6) 20 (65.6)
Additional Gas Amount g/m (oz/ft) 30 (0.3) 30 (0.3)
Piping
Length for Additional Gas m (ft) 10 (32.8) 10 (32.8)
Inner Diameter mm 16.7 16.7
Drain Hose
Length mm 650 650
Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat)
Fin Type Slit Fin Slit Fin
Row × Stage × FPI 2 × 15 × 21 2 × 15 × 21
Indoor Heat
Exchanger
Size (W × H × L) mm 25.4 × 315 × 810 25.4 × 315 × 810
Fin Material Aluminium (Blue Coated) Aluminium (Blue Coated)
Fin Type Corrugated Fin Corrugated Fin
Row × Stage × FPI 2 × 30 × 19 2 × 44 × 19
Outdoor Heat
Exchanger
Size (W × H × L) mm 38.1 × 762 × 985.8:865.8 38.1 × 1117.6 × 863.8:833.8
Material Polypropelene Polypropelene
Air Filter
Type One-touch One-touch
Power Supply Outdoor Power Supply Outdoor Power Supply
Power Supply Cord A Nil Nil
Thermostat - -
Protection Device - -
Dry Bulb Wet Bulb Dry Bulb Wet Bulb
Maximum 32 23 32 23
Cooling
Minimum 16 11 16 11
Maximum 30 - 30 -
Indoor
Operation
Range
Heating
Minimum 16 - 16 -
Maximum 46 26 46 26
Cooling
Minimum 5 4 5 4
Maximum 24 18 24 18
Outdoor
Operation
Range
Heating
Minimum -15 -16 -15 -16
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Specifications are subjected to change without prior notice for further improvement.
4. Maximum heating capacity shown are the values based on powerful operation.

Table of Contents

Other manuals for Panasonic CU-RE28PKR

Related product manuals