37
11.1.2.4 Connect the Cable to the Indoor Unit
1 The inside and outside connecting cable can be
connected without removing the front grille.
2 Connecting cable between indoor unit and
outdoor unit shall be approved polychloroprene
sheathed 4 × 1.5 mm
2
flexible cord, type
designation 245 IEC 57 or heavier cord.
3 Bind all the indoor and outdoor connecting
cable with tape and route the connecting cable
via the escapement.
4 Remove the tapes and connect the connecting
cable between indoor unit and outdoor unit
according to the diagram below.
5 Secure the connecting cable onto the control board with the holder (clamper).
o Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s
respectively.
o Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.