EasyManua.ls Logo

Panasonic CU-RE28PKR - Powerful Mode Operation; Economy Mode Operation; Timer Control

Panasonic CU-RE28PKR
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
55
C. Control contents
a. Fan Speed manual
1 Fan speed is changed from normal setting to quiet setting of respective fan speed.
This is to reduce sound of Hi, Me, Lo for 3dB.
2 Fan speed for quiet operation is reduced from setting fan speed.
b. Fan Speed Auto
1 Indoor FM RPM depends on pipe temp sensor of indoor heat exchanger.
12.7 Powerful Mode Operation
When the powerful mode is selected, the internal setting temperature will shift lower up to 2°C (for Cooling/Soft
Dry) or higher up to 3.5°C (for Heating) than remote control setting temperature for 20 minutes to achieve the
setting temperature quickly.
12.8 Economy Mode Operation
This operation is used to reduce electrical power consumption by adjusting the set temperature.
Economy operation starts when the Economy button is pressed during cooling or dry or heating operation.
During Cooling/Dry economy operation, target setting temperature will be adjusted by +2°C. Internal setting
temperature limit shift to maximum 35°C (maximum 33°C + 2°C Economy shift).
During heating economy operation, target setting temperature will be adjusted by -3°C. Internal setting
temperature limit shift to minimum 13°C (minimum 16°C - 3°C Economy shift).
During Patrol individual operation, economy operation could not be started.
During Economy operation, all indicators includes Economy indicator will be dimmed. The brightness level is
equivalent to indicator dim function.
Powerful, Quiet and Economy could not be operated at the same time. The unit will follow the latest setting of
these four operations.
The Economy operation stops when:
i. Operation OFF
ii. Received Economy signal from remote control again.
iii. Received either Powerful or Quiet operation signal from remote control.
12.9 Timer Control
There are 2 sets of ON and OFF timer available to turn the unit ON or OFF at different preset time.
If more than one timer had been set, the upcoming timer will be displayed and will activate in sequence.
12.9.1 ON Timer Control
ON timer 1 and ON timer 2 can be set using remote control, the unit with timer set will start operate earlier than
the setting time. This is to provide a comfortable environment when reaching the set ON time.
60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to
determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting
time.
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
12.9.2 OFF Timer Control
OFF timer 1 and OFF timer 2 can be set using remote control, the unit with timer set will stop operate at set time.