EasyManua.ls Logo

Panasonic CU-RE28PKR - Detailed Safety Instructions; Electrical Safety and Fire Prevention; Indoor Unit Care and Hazards; Remote Control Battery Guidelines

Panasonic CU-RE28PKR
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
2. Specifications
Indoor CS-RE18PKR
Model
Outdoor CU-RE18PKR
Performance Test Condition AS
Phase, Hz Single, 50
Power Supply
V 230 240
Min. Mid. Max.
kW 0.90 5.00 5.80
BTU/h 3070 17100 19800
Capacity
kcal/h 770 4300 4990
Running Current A 6.0 5.8
Input Power W 230 1.30k 2.05k
W/W 3.91 3.85 / 2.5 2.83
Btu/hW 13.35 13.15 9.66
EER
kcal/hW 3.35 3.31 2.43
Power Factor % 94 93
dB-A 47 / 34 / 31
Indoor Noise (H / Lo / QLo)
Power Level dB 63 / 50 / 47
dB-A 48 / - / 43
Cooling
Outdoor Noise (H / Lo / QLo)
Power Level dB 62 / - / 57
kW 0.90 6.35 6.40
BTU/h 3070 21700 21800
Capacity
kcal/h 770 5460 5500
Running Current A 7.6 7.5
Input Power W 260 1.69k 1.71k
W/W 3.46 3.76 / 2.5 3.74
Btu/hW 11.81 12.84 12.75
COP
kcal/hW 2.96 3.23 3.22
Power Factor % 97 94
dB-A 44 / 33 / 29
Indoor Noise (H / Lo / QLo)
Power Level dB 60 / 49 / 45
dB-A 48 / - / 43
Heating
Outdoor Noise (H / Lo / QLo)
Power Level dB 62 / - / 57
Capacity kW 4.6
Input Power kW 1.51
H2
COP W/W 3.05
Capacity kW 6.40
Input Power kW 1.71
Powerful Heat
COP W/W 3.74
Max Current (A) / Max Input Power (W) 11.9 / 2.65k
Starting Current (A) 7.6
Type Hermetic Motor (Rotary)
Motor Type Brushless (6-poles)
Compressor
Output Power W 900