12.4.1 Vertical Airflow
Vane Angle (°)
Operation Mode Airflow Direction
1 2 3 4 5
A 20
B 45
Auto with Heat Exchanger
Temperature
C 32
Heating
Manual 20 32 45 57 68
Auto 20 ~ 45
Cooling
Manual 20 26 32 37 45
Auto 20 ~ 45
Soft Dry
Manual 20 26 32 37 45
1 Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the
angles as stated above. For heating mode operation, the angle of the vane depands on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop. When the air conditioner
is stopped using remote control, the vane will shift to close position.
2 Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above
and the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control,
the vane will shift to close position.
12.4.2 Horizontal Airflow
1 Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within
the angles as stated below. For heating mode operation, the angle of the vane depends on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop.
Operation Mode Vane Angle (°)
A 68 ~ 112
Heating, with heat exchanger temperature
B 90
Cooling and Soft Dry 68 ~ 112