EasyManua.ls Logo

Panasonic CU-RE28PKR - Connect the Cable to the Outdoor Unit; Piping Insulation

Panasonic CU-RE28PKR
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
11.1.3.4 Connect the Cable to the Outdoor Unit
1 Remove the control board cover from the unit
by loosening the screw.
2 Cable connection to the power supply through
Isolating Devices (Disconnecting means).
o Connect approved type polychloroprene
sheathed power supply cord 3 × 2.5 mm
2
(2.0 ~ 2.5HP) type designation 245 IEC 57
or heavier cord to the terminal board, and
connect the others end of the cord to
Isolating Devices (Disconnecting means).
3 Connecting cable between indoor unit and
outdoor unit shall be approved polychloroprene
sheathed 4 x 1.5 mm
2
flexible cord, type
designation 245 IEC 57 or heavier cord.
4 Connecting cable between outdoor unit and
DRED (Demand response enabling devices)
shall be double insulation layer,
polychloroprene sheathed (> 50V) with size 4 ×
(0.5 mm
2
to 2.0 mm
2
) cable or flexible cord,
where the maximum allowable length is 30 m.
5 Connect the power supply cord and connecting
cable between indoor unit and outdoor unit
according to the diagram below.
6 Secure the power supply cord and connecting cable onto the control board with the holder.
7 Attach the control board cover back to the original position with screw.
8 For wire stripping and connection requirement, refer to instruction 5 of indoor unit.
Note: Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.
Always ensure all above connections compliant with national wire rules.
11.1.3.5 Piping Insulation
1 Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation
Diagram. Please wrap the insulated piping end to prevent water from going inside the piping.
2 If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by
using POLY-E FOAM with thickness 6 mm or above.

Table of Contents

Other manuals for Panasonic CU-RE28PKR

Related product manuals