7
Indoor CS-RE18PKR
Model
Outdoor CU-RE18PKR
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 12.70 (1/2)
Standard length m (ft) 5.0 (16.4)
Length range (min – max) m (ft) 3 (9.8) ~ 20 (65.6)
I/D & O/D Height Different m (ft) 15 (49.2)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Piping
Length for Additional Gas m (ft) 10 (32.8)
Inner Diameter mm 16.7
Drain Hose
Length mm 650
Fin Material Aluminium (Pre Coat)
Fin Type Slit Fin
Row × Stage × FPI 2 × 15 × 19
Indoor Heat
Exchanger
Size (W × H × L) mm 810 × 315 × 25.4
Fin Material Aluminium (Blue Coated)
Fin Type Corrugated Fin
Row × Stage × FPI 2 × 36 × 18
Outdoor Heat
Exchanger
Size (W × H × L) mm 36.4 × 756 × 839:810.6
Material Polypropelene
Air Filter
Type One-touch
Power Supply Outdoor Power Supply
Power Supply Cord A Nil
Thermostat -
Protection Device -
Dry Bulb Wet Bulb
Maximum 32 23
Cooling
Minimum 16 11
Maximum 30 -
Indoor
Operation
Range
Heating
Minimum 16 -
Maximum 46 26
Cooling
Minimum 5 4
Maximum 24 18
Outdoor
Operation
Range
Heating
Minimum -15 -16
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Specifications are subjected to change without prior notice for further improvement.
4. Maximum heating capacity shown are the values based on powerful operation.