1. Before switch "ON" electricity supply, please check the electrical wiring connection to the Unit.
Switch “ON” the Miniature Circuit Breaker (MCB) and ON/OFF DP (double pole) Switch.
Set the ELB of the Unit to “On”. (Push up the ELB Reset Lever if it is down)
Push the ELB Test Button.
It is normal if the ELB turns “Off” (the ELB Reset Lever falls) push the ELB Reset Lever up.
Refer figure as shown.
Inspect the built-in ELB (once a month) to avoid a hazard to users such as damage to property, serious
injury or death.
2. Turn "ON" the Main Water Valve.
Turn the Water Volume Knob clockwise and water will flow out from the Shower Head.
Check if water leaks from Pipe Line.
3. Turn the Main Switch Knob “On” (ELB lamp will lights).
Turn the Power Control Knob clockwise and hot water will flow out from the Shower Head.
(Adjust to suitable water temperature).
4. Refer detail for HOW TO USE and WATER FLOW RATE ADJUSTMENT on page 15.
3. TEST OPERATION
WARNING
MUST BE TIGHTEN
L(+) (-)N
Front Plate
“D-Cut”
Position
Main Switch Knob and Power Control Knob
Front Plate
Back Plate
Press
Press
Press
Make sure the Main Switch Knob and the Power
Control Knob on Front Plate and it is at “Off” position.
Make sure the “D-Cut” position of the Rotary Shaft and
VR Shaft are located as shown.
Close the Front Plate of the Unit according to the sequence
as illustrated.
Push in the Main Switch Knob and Power Control Knob
until it is fully inserted
<Main Switch Knob and Power Control Knob can not be
inserted if Step (1) and Step (2) is not done accordingly>
Fix the screw at the bottom of the Unit.
Note:
Do not push the ELB Test Button during fixing the Front
Plate.
Do not apply extreme force to insert the Main Switch Knob
and Power Control Knob during fixing the Front Plate
because it will damage the switch inside the Unit.
6. How to fix the Front Plate
Mount the Shower Hanger on the wall with 2 Screws.
Drive each Screws into the 2 Wall Plugs through the screw holes.
Make sure the Shower Head top is not higher than the Unit top when installing the Shower Hanger.
7. Shower Hanger Installation
Screw
Shower Hanger
Wall Plug
Screw
Shower Hanger
Shower Head
O
P
E
N
C
L
O
S
E
FILTER
CLEANING
OFF
MAX
If the ELB Reset Lever cannot be reset even if you push it up or if it soon slides down
during operation, please do not use the Unit and contact the authorized dealer
immediately to avoid a hazard to users such as damage to property, serious injury or
death. Never fix the ELB Reset Lever forcibly with tape and such.
WARNING
Push
ELB
Test Button
ELB
Reset Lever
ENGLISH
INSTALLATION
Screw
ELBTest
ELBReset
PushUp
DH-3RL1
ELB
Off
Off
On
High
P
o
w
e
r
C
o
n
t
r
o
l
M
a
i
n
S
w
i
t
c
h
ELB
Off High
Off On
P
o
w
e
r
C
o
n
t
r
o
l
M
a
i
n
S
w
i
t
c
h

Related product manuals