Display Description
1 There was no change of mechanism position. (Loading Motor was OFF)
2 There was some change of mechanism position. (Loading Motor was ON)
12.5. (VHS) Description of Self Diagnosis Memory
In this Self-Diagnosis Function, in case error has occurred continuously, maximum of the newest 3 error data are memorized.
And in order to analyze cause of error, the error number and the supplementary data of mode, mechanism position and so on are memorized.
12.5.1. (VHS) Error Number and Supplementary Data
The Supplementary Data as shown below are memorized to each error number.
Error
No.
Reason Supplementary Data
Data 1 Data 2 Data 3 Data 4
01 The cylinder could not be started.
(Error of the cylinder or the cylinder
driver.)
VHS mode - - -
02 The CAP FG could not be detected. VHS mode - Process
No.
Number of FG
03 Mechanism lock during without the
unloading and the cassette-up.
VHS mode Standby position Process
No.
LM information
04 Mechanism lock during unloading VHS mode - Process
No.
LM information
68