9. Programmable Features
70
Setting the font number in
PCL
{#}{7}{6}{9}
To set the font number to be used in PCL printing. The unit assigns a number
to each font.
1. {Menu} i {#}{7}{6}{9} i {Set}
2. Enter the font number from 000 to 054, using the dial keypad.
L The default setting is 000.
3. {Set} i {Menu}
Note:
L If the font source in PCL (feature #768 on page 69) is set to Download
Font, the default setting is 001.
L To print the font list, see page 103.
Setting the font pitch/point in
PCL
{#}{7}{7}{0}
To set the font pitch/point to be used in PCL printing.
1. {Menu} i {#}{7}{7}{0} i {Set}
2. Enter the font pitch from 00.44 to 99.99, or the point from 004.00
to 999.75, using the dial keypad.
L The default pitch is 10.00 and the default point is 012.00.
L The setting will be either font pitch or point depending on the font
number selected in feature #769 (page 70).
3. {Set} i {Menu}
Setting the symbol set in PCL
{#}{7}{7}{1}
To set the symbol set to be used in PCL printing.
1. {Menu} i {#}{7}{7}{1}
2. Press {V} or {^} repeatedly to display the desired symbol set. i {Set}
i {Menu}
Setting the line breaks in PCL
{#}{7}{7}{2}
To set each behavior when receiving CR, LF, and FF codes.
{1} CR/LF/FF (default): CR=CR, LF=LF, FF=FF
{2} CR+LF/LF/FF: CR=CR+LF, LF=LF, FF=FF
{3} CR/CR+LF/CR+FF: CR=CR, LF=CR+LF, FF=CR+FF
Setting the waiting time for
auto continue mode
{#}{7}{7}{3}
To set the length of time before the unit recovers if a memory overflow occurs.
{1} Off (default): Deactivates this feature.
{2} 20s: 20 seconds
{3} 30s: 30 seconds
{4} 60s: 60 seconds
{5} 90s: 90 seconds
{6} 120s: 120 seconds
Changing the data timeout
setting
{#}{7}{7}{4}
The unit will automatically print the remaining data in memory when the
computer does not send data to the unit during the set time.
1. {Menu} i {#}{7}{7}{4} i {Set}
2. Enter the desired data timeout setting from 005 seconds to 600
seconds, using the dial keypad.
L The default setting is 060 seconds.
3. {Set} i {Menu}
Setting mutual A4/letter print
{#}{7}{7}{6}
This feature allows printing in A4-size even if letter-size recording paper is
loaded, and vice versa.
{0} Off: Deactivates this feature.
{1} On (default): Printing is possible between A4/letter-size.
Feature/Code Selection