High−level Instructions
3 − 500
For FP−X Tr type
Channel
no.
Control
flag
Elapsed value
area
Target value area
Near
home
home
input
ch0
R91
1C
DT90348 DT90350
X4
c
h
0
R
911
C
DT90349 DT90351
X
4
ch1
R91
1D
DT90352 DT90354
X5
c
h
1
R
911
D
DT90353 DT90355
DT90052
X
5
ch2
R91
1E
DT90356 DT90358
DT90052
<bit4>
X6
c
h
2
R
911
E
DT90357 DT90359
X
6
ch3
R91
1F
DT90360 DT90362
X7
c
h
3
R
911
F
DT90361 DT90363
X
7
Note) There is no ch3 for C14T and C14TD.
Operation modes
Return to home position
Pulses are output continually until home input (X2 or X5) occurs. To decelerate at near home, set the
corresponding bit of special data register DT90052 off → on → off when near home input occurs.
The value in the elapsed value area during a home position return differs from the current value. When the
return is completed, the elapsed value changes to 0.
Home position return by means of near home input and home input
Deceleration occurs when near home input occurs, and pulse output stops after home input. Operation
varies depending on the control code (lower order) settings described on the following page.
f
t
Near home input
Fmax
Fmin
home input
Home position return using only home input
Pulse output stops when home input occurs. Use a control code (lower order) setting on the following page
from H20 to H27.
f
t
Fmax
Fmin
home input
FPΣ/FP−X