2.145. Query IN STANDBY MODE
Hexadecimal 02h 51h 56h 58h 3Ah
41h 53h 42h 49h 30h
Character Q V X : A S B I 0
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 41h 53h 42h 49h 30h 3Dh 2Dh
Character A S B I 0 = +
Hexadecimal *1 *3 *5 *7 *9 03h
Character *2 *4 *6 *8 *10
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10)
OFF
Hexadecimal 30h 30h 30h 30h 30h
Character 0 0 0 0 0
ON
Hexadecimal 30h 30h 30h 30h 31h
Character 0 0 0 0 1
2.146. Query DVI SIGNAL LEVEL
Hexadecimal 02h 51h 56h 58h 3Ah
44h 56h 49h 49h 30h
Character Q V X : D V I I 0
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 44h 56h 49h 49h 30h 3Dh 2Dh
Character D V I I 0 = +
Hexadecimal *1 *3 *5 *7 *9 03h
Character *2 *4 *6 *8 *10
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
× ×
Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10)
0-255:PC
Hexadecimal 30h 30h 30h 30h 30h
Character 0 0 0 0 0
16-235
Hexadecimal 30h 30h 30h 30h 31h
Character 0 0 0 0 1
2.147. Query WARNING MESSAGE
Hexadecimal 02h 51h 56h 58h 3Ah
57h 4Dh
44h 49h 30h
Character Q V X : W M D I 0
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 57h 4Dh 44h 49h 30h 3Dh 2Dh
Character W M D I 0 = +
Hexadecimal *1 *3 *5 *7 *9 03h
Character *2 *4 *6 *8 *10
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10)
OFF
Hexadecimal 30h 30h 30h 30h 30h
Character 0 0 0 0 0
ON
Hexadecimal 30h 30h 30h 30h 31h
Character 0 0 0 0 1