(Dark-ON)
<Teaching mode>
<Output operation setting mode>
(Light-ON)
<Timer operation setting mode>
(Without timer)
(ON delay timer)
(OFF delay timer)
<Timer delays setting mode> <Timer delays setting mode>
(Timer delay)
(Timer delay)
: Select timer delays from 1ms, 5ms, 10ms, 20ms, 40ms, 50ms,
100ms, 500ms, and 1,000ms.
<Emission amount setting mode>
(Level 3)
(Level 2) (Level 1)
(Auto + Level 3)
(Note 1)
<Emission frequency setting mode (Note 2)>
In case of FX-101□
: Select emission frequency from
“
”, “ ”, “ ” or “ ”
: Select emission frequency from
“
”, “ ”, “ ” or “ ”
(Emission frequency 0)
(Emission frequency 1)
<RUN mode>
In case of FX-102□
In case of FX-101□
In case of FX-102□
Notes: 1) When selecting Auto (displayed with “
”), proper light intensity (“ ”, “ ” or “ ”) is automatically
decided when only the limit teaching is set. (“
”isindicatedatrstselecting.)
In Auto, emission amount is automatically set to let the incident light intensity in proper range (1000 to 3800).
2) The operation indicator and the beam-emitting inlet blink while setting emission frequency. (When emission
frequency 0 is set, they light up.) The blinking cycle depends on each emission frequency.
(Emissionfrequency1:fast↔Emissionfrequency4:slow)
Setting item Factory setting Description
Teaching mode
Threshold value can be set in 2-point teaching, limit teaching or full-auto
teaching.
For details, refer to “
TEACHING MODE.”
Output operation
setting mode
Light-ON or Dark-ON can be set.
Timer operation
setting mode
Without timer, ON delay timer or OFF delay timer can be set.
Timer delays setting
mode
When setting ON delay timer or OFF delay timer in the timer operation set-
ting mode, timer delays can be set.
● When timer is not set, this mode is not displayed.
Emission amount
setting mode
In case incident light intensity is saturated, emission amount can be re-
duced. The reduced intensity state can also be released.
Level 3 “
”: Normal emission amount level
Level 2 “ ”:Emissionamountlevel3×approx.40%
Level 1 “ ”:Emissionamountlevel3×approx.20%
When selecting Auto, displayed with “
. ” Only in the limit teaching, proper
light intensity is automatically set.
Emission frequency
setting mode
FX-101□
FX-102□
Whenusing theber headsinparallel, interferencecan bepreventedby
setting different emission frequency. However, when emission frequency 0 is
set, interference cannot be prevented. Response time corresponds to emis-
sion frequency. For details, refer to “
SPECIFICATIONS.”
7 TEACHING MODE
Make sure that detection may become unstable if less margin is applied in the use
environment when teaching.
In case of 2-point teaching
● This is the method of setting the threshold value by teaching two points, corre-
sponding to object present and object absent conditions. Normally, setting is done
by this method.
● TheoutputoperationsettingofLight-ONorDark-ONisreectedautomatically.
<For output ON when in object present condition>
<Teaching mode>
AUTO
AUTO
• Press ON key in object
present condition.
Thru-beam type
Light interrupted
condition
Reectivetype
Mark
Base
Light received condition
• Therstincidentlightintensityissetandindicatedonthegreendigitaldisplay.
Cancellationofthesettingfortherstincidentlightintensityispossiblewhen
MODE key is pressed.
• The present incident light
intensity blinks in red at
the digital display.
• Press OFF key in object
absent condition.
Thru-beam type
Light received condition
Reectivetype
Mark
Light interrupted condition
Base
• Thethresholdvaluewhichissetbetweentherstandthesecondincidentlightintensityis
indicated on the green digital display.
• Marginforthethresholdvaluetotherstorthesecondincidentlightintensityisindicat-
ed on the red digital display. When the margin is 200% or more, “
” is displayed.
• The setting is done.
<For output ON when in object absent condition>
<Teaching mode>
AUTO
AUTO
• Press ON key in object
absent condition.
Thru-beam type
Light received condition
Reectivetype
Mark
Light interrupted condition
Base
• Therstincidentlightintensityissetandindicatedonthegreendigitaldisplay.
Cancellationofthesettingfortherstincidentlightintensityispossiblewhen
MODE key is pressed.
• The present incident light
intensity blinks in red at
the digital display.
• Press OFF key in object
present condition.
Thru-beam type
Light interrupted condition
Reectivetype
Light received condition
Mark
Base
• Thethresholdvaluewhichissetbetweentherstandthesecondincidentlightintensityis
indicated on the green digital display.
• Marginforthethresholdvaluetotherstorthesecondincidentlightintensityis indicated
on the red digital display.
• The setting is done.
In case of limit teaching
● This is the method of setting the threshold value by teaching only the object absent
condition (stable incident light condition). This is used for detection in the presence of
a background body or for detection of small objects.
● When selecting “Auto” (displayed with “ ”) in the emission amount setting mode, proper light
intensity can be automatically set. For the setting method, refer to “
SETTING MODE.”
<Teaching mode>
or
AUTO
or
AUTO
• Press OFF key (the threshold value is
shifted to lower side) twice when using
thru-beam type fiber, and press ON key
(the threshold value is shifted to higher
side)twicewhenusingreectivetypeber.
Thru-beam type
Reectivetype
Back
ground
• Reference incidentlight intensityissetbytherst keyinput andindicatedonthe green
digital display.
Cancellation of the setting for the reference incident light intensity is possible when
MODE key is pressed.
• The present incident light intensity blinks in red at the digital display.
• Press ON key or OFF key which is pressed in the previous step.
Forexample,whenONkeyispressedinthepreviousstep,pressONkeyagainfor
the second time.
The incident light intensity at the second key input is not related to the threshold value.
The set threshold value is indicated on the green digital display.
• The threshold value depends on the shift amount. For setting method of the shift
amount, refer to <Shift setting mode> in “
PRO MODE.”
• Margin for the threshold value to the inci-
dent light intensity is indicated on the red
digital display. When the margin is 200%
or more, “
” is displayed.
• The setting is done.
High
Threshold
value
Low
15%
15%
Threshold value
Incident light intensity
with object absent
Press
Threshold value
Press
In case of full-auto teaching
● Full-auto teaching is used when it is desired to set the threshold value without stop-
ping the assembly line, with the object in the moving condition.
<Teaching mode>
or
Hold down
AUTO
AUTO
• Hold down ON key or OFF key.
•“
”appearsinthe greendigitaldisplayafter approx.2sec.,and startssampling
the incident light intensity from that point.
• The threshold value is set when ON key or OFF key is released.
• The set threshold value is indicated on the green digital display.
• Margin for the threshold value to the incident light intensity is indicated on the red digi-
tal display. When the margin is 200% or more, “
” is displayed.
• The setting is done.
8 PRO MODE
● PRO mode appears after pressing MODE key for 4 sec. in RUN mode.
● RUN mode appears when MODE key is pressed for 2 sec. while setting and the
changed contents have been set.
● Make sure to return to RUN mode before turning OFF the power. If the power is
turned OFF while setting, the changed contents have not been set.
<RUN mode>
<PRO mode>
Press for 4 sec.
<Shift setting mode>
: Select the shift amount from 0 to 80%
(15%)
<Externalinputsettingmode>
(Emission halt)
(Limit teaching [-])(Limit teaching [+])
<Threshold value follow-up cycle setting mode>
Threshold value-storing setting mode is not indicated unless any
of “
”, “ ”, “ ” or “ ”issetattheexternalinput
setting mode.
(Full-auto teaching)
(2-point teaching)
<Threshold value-storing setting mode>
(Incident light intensity test)
(ECO)
AUTO