Panasonic FX-100 Series - Teaching Mode; Teaching Methodologies; Pro Mode; Advanced Parameter Configuration

Panasonic FX-100 Series
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
<Threshold value follow-up cycle setting mode>
<Externalinputsettingmode>
(OFF)
(Under 60 sec.)
: Select a target value from 0 to 2,000
(100 unit each) to correct the incident
light intensity.
(2,000)
<GETA function setting mode>
(10 to 60 min. or less)(1 to 9 min. or less)
(OFF)
(SET)
<ECO setting mode>
<Inverting digital display setting mode>
(OFF) (ON)
(OFF) (ON)
<Threshold value margin setting mode>
(OFF) (Green blinks)
(Red blinks)
(Red and Green blink)
Alertoutputofexternal
input teaching
Alertoutputof externalinputteachingdoes not
operate unless any of “ ”, “ ” or “ ” is
setattheexternalinputsettingmode.
<Setting copy mode>
(YES)(NO)
(READY)
<Reset mode>
(YES)(NO)
<RUN mode>
Turn the power off when copying the settings.
: Cancellation is possible when
pressed for 2 sec. or more.
Setting item Factory setting Description
Shift setting mode
Shift amount can be selected from 0 to 80% in the limit teaching.
Select 0% when it is desired to set the present incident light intensity as a
threshold value.
Externalinput
setting mode
Externalinput canbe selectedfromemissionhalt, limitteaching[+],limit
teaching [-], full-auto teaching, ECO (Note 1), 2-point teaching or emission
amount test.
When setting the incident light intensity test “ ”, output turns ON / OFF
every 100ms when the rate of incident light intensity and threshold value is less
thanhalfofthesetshiftamount(forexample,whentherateofincidentlightinten-
sityandthresholdvalueiswithin±10%for20%ofshiftamount)atexternalinput.
Threshold value-
storing setting mode
(Note 2)
Threshold value set at the limit teaching, full-auto teaching or 2-point teach-
ingbyexternalinputisstored.WhenselectingAutointheemissionamount
setting mode, the set emission amount level is also stored.
Threshold value
follow-up cycle setting
mode (Note 3)
Whenincidentlightintensityexceedsthreshold value,this modecan changethe
threshold value with each set cycle depending on variations of the incident light in-
tensity. The follow-up shift amount is same as the one set in the shift setting mode.
However, the threshold value is not stored.
GETA function setting
mode (Note 4, 5)
Variations can be reduced by correcting the present incident light intensity in
eachampliertoatargetvalue.Targetvaluetooffsetincidentlightintensity
can be selected from 0 to 2,000 by 100 unit each.
Forexample,ifthetargetvalueissetto2,000whentheincidentlightinten-
sity is 1,500, the incident light intensity becomes 2,000.
ECO setting mode
It is possible to light up / turn off the digital display. When ECO setting mode
isON,thedisplayturnsoffinapprox.20sec.inRUNmode.Tolightupthe
display again, press any key for 2 sec. or more.
Inverting digital
display setting mode
Digital display can be inverted.
Threshold value
margin setting mode
Margin for threshold value to the present incident light intensity can be checked.
When there is no margin, it is possible to make the digital display blink.
: Green blinks.
”: : Red blinks.
: Red and Green blink.
” :
Whenconductinglimitteachingor2-pointteachingbyexternalinput,
in case the rate of reference incident light intensity and threshold
value after teaching is 200% or more, or in case it is less than half of
the shift amount, output turns ON / OFF every 100ms. (Note 6)
Setting copy mode
Thesettingsof themaster sideamplier canbe copiedto theslave side
amplier.Fordetails,referto“
SETTING COPY FUNCTION.”
Reset mode
Returns to default settings (factory settings).
Notes: 1) WhenECOisselected attheexternalinputsetting mode,key operationon themainbodyisinvalid during
externalinput.
2) This mode is not indicated unless any of
”,
”,
or
isset atthe externalinput
setting mode.
3) If the incident light intensity becomes “300” or less, the follow-up operation stops.
In that condition, threshold value [digital display (green)] blinks.
Thisfunctioncanbeusedwhenthru-beamtypeorretroreectivetypeberisappliedtothisproduct.Ifreec-
tivetypeberisapplied,thefunctioncannotbeuseddependingonuseconditions.
4) If pressing MODE key in RUN mode when GETA function is used, the incident light intensity before setting
GETAfunctionisdisplayedonthereddigitaldisplayforapprox.2sec.
5) When GETA function is used in saturation of incident light intensity (4,000 or more), “ ” is indicated on
the red digital display. Correction value is up to 4,000.)
6) This mode does not operate unless any of “ ”, “ ” or “ ” isset atthe externalinputsetting
mode.
9 EXTERNAL INPUT SETTING
Whenselectingemissionhaltin theexternalinputsetting modeandreceivingthe
signalexternally,“
” is indicated on the red digital display.
WhenselectingECOintheexternalinputsettingmode,keyoperationonthemain
bodyisinvalidduringexternalinput.
Whenselecting2-pointteachingintheexternalinput settingmode,
” is indi-
catedonthegreendigitaldisplayafterinputtingtherstpoint.
Forthesettingofexternalinput,referto“
PRO MODE.”
<Time chart when setting external input>
Externalinputsignal
Emisson halt
(Note 1)
Limit
teaching
Full-auto
teaching
(Note 4)
ECO mode
2-level
teaching
25ms or more
20ms or more
20ms
(Note 2)
Emission
NPN output
type: Low
High
Low
NPN output
type: High
20ms
20ms 20ms
Emission halt
20ms
20ms
Teaching in progress
Normal operation
20ms
Teaching in progress
Sampling in
progress
20ms
20ms
20ms
Normal operation
20ms 20ms
20ms
20ms
ECO in progress
Normal operation
20ms
First point Second point
20ms
Teaching in progress
Normal operation
(Note 3)
(Note 5)
(Note 2)
Notes: 1) Output may turn ON / OFF when emission is halted or is released depending on setting of threshold value.
2) When emission starts, output operation will be undetermined only during the response time.
IftheoutputsignalisreceivedbysomethingsuchasaPLC,setthetimertoavalueof20msamplierresponsetimeorgreater.
Example:FortheFX-101□withemissionfrequency0(responsetime250µsorless)
Timerperiod:20ms+0.25ms(250µs)=20.25ms
3) After teaching is complete, output operation will be undetermined only during the response time. If the output
signalisreceivedbysomethingsuchasaPLC,setthetimertotheamplierresponsetimeorgreater.
Thethresholdvaluewillbesetbasedontheincidentlightintensityattheinstantwhenteachingisveried.
4) Movethesensingobjectpastonceduringthetimethattheexternalinputsignalisbeinginput.
5) After teaching is complete, output operation will be undetermined only during the response time. If the output
signalisreceivedbysomethingsuchasaPLC,setthetimertotheamplierresponsetimeorgreater.
<Alert output of external input teaching>
Whenconducting limitteachingor2-point teachingbyexternalinput, ifthealertoutput of
externalinputteaching
” is set in the threshold value margin setting mode, output
turns ON / OFF every 100ms in case the rate of reference incident light intensity and thresh-
old value after teaching is 200% or more, or in case it is less than half of the shift amount.
For the setting method, refer to <Threshold value margin setting mode> under “
PRO MODE.”
Externalinputsignal
25ms or more
20ms or more
High
Low
NPN output
type: Low
NPN output
type: High
Limit teaching
20ms
20ms
Teaching in progress
Normal operation
Output operation
when selecting
alert output of
externalinput
teaching
100ms 100ms
(Note 1)
(Note 1)
100ms 100ms
ON
OFF
2-level teaching
20ms
First point
20ms
Second point
Teaching in progress
Normal operation
ON
OFF
(Note 2)
Output operation
when selecting
alert output
ofexternal
input teaching
100ms
100ms
Notes: 1) Incasethemarginisno good,output turnsON /OFF every100ms duringthe timethat theexternal input
signal is being input after teaching.
2) Incase themargin isno good,output turnsON /OFF every100ms duringthe timethat theexternal input
signal is being input after the second teaching.
10
SETTING COPY FUNCTION
Thiscancopythesettingsofthemastersideampliertotheslavesideamplier.
Be sure to use the setting copy function between the identical models. This func-
tion cannot be used between different models.
Only one sensor can be connected on slave side with a master side sensor for the setting copy function.
Threshold value, output operation setting, timer operation setting, timer setting, emission
amountsetting,shiftsetting,externalinput setting,thresholdvalue-storingsetting,ECO
setting, inverting digital display setting, and threshold value margin setting can be copied.
Setting procedures
1. Setthesettingcopymodeofthemastersideamplierto“CopysendingON,”andpress
MODE key so that “
” is shown on the digital display and the sensor is in copy
ready state. For the setting method, refer to <Setting copy mode> in “
PRO MODE.”
2. Turnoffthemastersideamplier.
3. Connectthemastersideamplierwiththeslavesideamplierasshownbelow.
Color code of cable with connector
(White)Externalinput
(Brown)+V
(Black)Input
(Blue)0V
Mastersideamplier
Slavesideamplier
(White)Externalinput
(Brown)+V
(Black)Input
(Blue)0V
Power supply