5
You can make fine adjustments to the threshold value while in ADJ mode.
Set the threshold value at least a bit higher than the minimum
threshold value. The minimum threshold value is reached when
you cannot lower it any further even though the jog switch is
turned to the “-” side.
For the output operation, you can select between Light-ON or Dark-ON.
In the timer operation mode, you choose amongst the following settings:
: no timer
: one-shot timer
: ON-delay timer
: OFF-delay timer
Set the timer interval in PRO1 mode.
For an even more detailed explanation of PRO mode, check out our Web
site for the “PRO Mode Operation Guide”, www.panasonic-electric-
works.com, or contact our office.
PRO mode overview
The 0-ADJ setting function was removed in May, 2005.
PRO mode detailed settings
1 Turn the jog switch to navigate between PRO modes.
2 Press the jog switch to enter a specific PRO mode.
3 Turn the jog switch to navigate between the settings within each specific
PRO mode.
10 THRESHOLD VALUE ADJUSTMENT MODE
Step Description
1 Press <MODE> briefly and repeatedly until the ADJ
operation indicator is lit.
2 Turn the jog switch to the “+” side to increase the
threshold value, i.e. decrease sensitivity, or to the “-
” side to lower the threshold value, i.e. increase sen-
sitivity.
3 Press the jog switch briefly to confirm the setting.
11 OUTPUT OPERATION MODE
Step Description
1 Press <MODE> briefly and repeatedly until the L/D
operation indicator is lit.
2 Turn the jog switch to switch between Light-ON (L-
on is displayed) and Dark-ON (D-on is displayed).
3 Press the jog switch briefly to confirm the setting.
12 TIMER OPERATION MODE
Step Description
1 Press <MODE> briefly and repeatedly until the TIMER
operation indicator is lit.
2 Turn the jog switch to the “+” or “-” side until the
desired timer mode is selected.
3 Press the jog switch briefly to confirm the setting.
13 PRO MODE
PRO1
: response time change
: stability
: timer setting
: shift
: hysteresis : emission level
PRO2
: digital display setting
: digital display inversion
: ECO mode setting
PRO3
: data bank load setting
: data bank save setting
PRO4
: setting condition copy
: communication lock
: remote data bank load
setting
: back-up
: remote data bank save
setting
PRO5
: code setting
: adjust lock setting
: reset