12.5 Clamp Assembly Removal and
Installation
(1) Remove
the
front
plate
as
described
in
section
12.2.
(2) Remove
the
shield
plate
as
described in section
12.1
step (1).
(3) Remove
the
two
clamp assembly
mounting
screws and
take
out
the
clamp assembly.
(4) Reverse
the
above procedure
to
reinstall.
Clamp Assembly
Fig.12-5 Clamp Assembly Removal
-16-
12.6
Write
Protect Sensor Assembly and Index
Sensor Assembly Removal and
Installation
(1)
Remove
the
shield
plate
as
described
in
section
12.1
step (1).
(2) Disconnect
the
J3
connector
from
PCB.
(3)
Draw
out
the
pi
ns
of
the
write
protect
sensor
assembly
from
the
following
locations on
the
13
connector:
N09,
11.
At
that
time,
draw
out
the
pins
with
lifting
the
stopper on
the
connector.
(4)
Draw
out
the
pins
of
the
index sensor assembly
from
the
following
locations
on
the
J3
connector:
NoS,
7.
At
that
time,
draw
out
the
pins
with
lifting
the
stopper on
the
connector.
(S)
Remove
the
write
protect
sensor
mounting
screw and index sensor
mounting
screw
respectively.
(6) Reverse
the
above procedure
to
reinstall.
(7)
When
reinstalling
the
write
protect
sensor,
exercise care
so
that
the
leads and
write
protect
sensor
will
not
project
from
the
bottom
and
side
of
the
base.
(8)
After
index sensor installation, adjust
the
index
burst
as
described
in
section 9.8.