Loading...
PLATEN
REMOVAL
AND
INSTALLATION
Removing
the
Platen
If you
have
to
remove the
platen
to
clear
a
gummed
label
or
clean
the platen,
please follow the
instructions
below;
1
Turn
the
power
off
2
Open the
top
cover
3
Pull
the
paper release
lever
and paper
bail release
lever toward
the front
of
the machine
4
Pull
both
black
levers
of
the
platen
holders
towards
the
front
of
the
machine
to
unlock
5
Lift
out
the
platen
46