PBX Connected via
Maximum Number
KX-T0151 KX-TDA0152 KX-T0141 KX-TDA0142
KX-NCP1000
• DHLC card
• DLC card
8 - 8 -
Required Distances between Equipment
CAUTION
Maintain the distances listed below between equipment in order to prevent noise, interference or the
disconnection of a conversation. (The distance may vary depending on the environment.)
Equipment Distance
CS and office equipment such as a computer, telex, fax
machine, etc., or microwaves
More than 2 m (6 ft 7 in)
CS and PS More than 1 m (3 ft 3 in)
Each CS More than 15 m (49 ft)
Each PS More than 0.5 m (1 ft 8 in)
PBX and CS More than 2 m (6 ft 7 in)
Notice
The required distance between CSs may vary depending on the environment of the installation site and
conditions in which the wireless system is used. Conduct a site survey to determine the appropriate
distance.
RF Specification
Item Description
Frequency Band 2400 MHz to 2483 MHz
Transmission Output Peak 0.25 W
CAUTION
• The CS should be kept free of dust, moisture, high temperature (more than 40
°C [104 °F]), low
temperature (less than 0 °C [32 °F]), and vibration, and should not be exposed to direct sunlight.
• The CS should not be placed outdoors (use indoors).
• The CS should not be placed near high-voltage equipment.
• The CS should not be placed on a metal object.
• Systems using 2.4 GHz ISM (Industrial, Scientific and Medical) band may interfere with the Panasonic
wireless system. Examples of such systems are cordless telephones, wireless LAN, Home RF,
microwave ovens and other ISM devices. These systems may cause minor noise.
Notice
Please
take into consideration the distance between the CSs when site planning. Please consult a certified
dealer for details.
8 Quick Installation Guide Document Version 2009-12
1 Overview