Note:
See the table below for frequently used commands.
Command name Function Example
rdeeprom Read the data of EEPROM Type “rdeeprom 00 00 FF”, and the data
from address “00 00” to “FF” is read out.
readid Read ID (RFPI) Type “readid”, and the registered ID is
read out.
writeid Write ID (RFPI) Type “writeid 00 18 E0 0E 98”, and the ID
“0018 E0 0E 98” is written.
setfreq adjust Frequency of RFIC Type “setfreq nn nn”.
Getchk Read checksum Type “getchk”.
Wreeprom write eeprom Type "wreeprom 01 23 45". "01 23" is
address and "45" is data to be written.
14. ADJUSTMENTS (BASE UNIT AND CHARGER UNIT)
If your unit have below symptoms, adjust or confirm each item using remedy column from the
table.
Symptom Remedy*
The base unit does not respond to a call from handset.
Make adjustments in item
)~(M)
The base unit does not transmit or the transmit frequency is off.
Make adjustments in item
(H)~(J), (L)
The transmit frequency is off.
Make confirmation in
(H)~(J), (L)
The transmit power output is low, and the operating distance between
base unit and handset is less than normal.
Make confirmation in
The reception sensitivity of base unit is low with noise.
Make confirmation in
The transmit level is high or low.
Make adjustments in item
The reception level is high or low.
Make adjustments in item
The unit does not link.
Make confirmation in
The unit cannot charge.
Make confirmation in
* : Refer to Adjustment (Base Unit) ()
14.1. Adjustment (Base Unit)
Please follow the items below when BBIC or EEPROM are replaced.
39
www.freeservicemanuals.info
Digitized in Heiloo, Holland