Items
Adjustment
Point
Procedure
(I) Modulatoin Check
and Adjustment
ANT Follow steps 1 to 3 of (H) above.
4. Confirm that the B-Field Modulation is 340kHz/div ~ 402kHz/
div using data type Fig31.
5. Adjust the B-Field Modulation if required. (Execute the
command "readmod" and "wrtmod xx", where xx is the value.)
(J) Frequency Offset
Confirmation
- Follow steps 1 to 3 of (H) above.
4. Confirm that the frequency offset is < ± 40kHz.
(K) Sensitivity
Receiver
Confirmation
- Follow steps 1 to 3 of (H) above.
4. Set DECT tester power to -88dBm.
5. Confirm that the BER is < 1000ppm.