Items
Adjustment
Point
Procedure
(J) Modulatoin Check
and Adjusment
TP15 Follow steps 1 to 4 of (I) above.
5. Confirm that the B-Field Modulation is 340kHz/div ~ 402kHz/
div using data type Fig31.
6. Adjust the B-Field Modulation if required. (Execute the
command "Readmod" and "Wrtmod xx", where xx is the value.)
(K) Frequency Offset
Confirmation
- Follow steps 1 to 4 of (I) above.
5. Confirm that the frequency offset is < ± 50kHz.
(L) Sensitivity
Receiver
Confirmation
- Follow steps 1 to 4 of (I) above.
5. Set DECT tester power to -88dBm.
6. Confirm that the BER is < 1000ppm.