EasyManua.ls Logo

Panasonic KX-TCD420BXM

Panasonic KX-TCD420BXM
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Items
Adjustment
Point
Procedure
Check
Replace
Parts
(P) Transmit Audio
Check and
Confirmation
TP15
1. Configure the DECT tester (CMD60) as follows;
<Setting>
-Test mode: FP
-Mode: Normal
-RFPI: 0102030405
2. Execute the command "testmode".
3. Execute the command "regcmd60".
4. Initiate connection from DECT tester.
5. Execute the command "openaudio".
6. Confirm that the value of EEPROM address "F3F" is "02". (If the value is not "02 (by
User)", set "02" and power off and power on, and return to clause 2.)
7. Input audio signal (30mVrms/1kHz tone) to DECT tester.
<DECT tester setting>
-Scramble: On
-AF Gen to ADPCM: Off
-AF Meter Input: ADPCM
-AF Gen Frequency: 1000Hz
-AF Gen Level: 30mVrms
8. Confirm hearing tone: 300mV ± 250mV (Just check Audio path)
9. Confirm that the audio distortion with DECT tester is < 5 %.
IC1,C8,R7,
R8,C6,C7,
C5,R5,R1,
C4,IC3,C54,
C66,C60,L3,
C57,C55,C56,
C62,R23,R24,
C63,C64,C65,
R18
Note:
After the measuring, sock up the solder of TP.
* : PC Setting () is required beforehand.
The connection of adjustment equipment are as shown in Adjustment Standard (Handset) ().
15.2. Adjustment Standard (Handset)
When connecting the Simulator Equipments for checking, please refer to below.
Note:
(A) - (P) is refered to ADJUSTMENTS (HANDSET) ()
16. RF SPECIFICATION
16.1. Base Unit
Item Value Refer to -. *
Remarks
TX Power More than 20 dBm ~ 25
dBm
Adjustment (Base Unit) (H)
Modulation 340 kHz/div ~ 402 kHz/div
Adjustment (Base Unit) (I)
Data type:
Fig31
Frequency Offset -50 kHz ~ +50 kHz
Adjustment (Base Unit) (J)
RX Sensitivity < 1000 ppm
Adjustment (Base Unit) (K)
Timing Accuracy < ± 5.0 ppm Adjustment (Base Unit) (L)
RSSI Level 0x34 hex ± A hex Adjustment (Base Unit) (M)