26
KX-TGP500B04/KX-TPA50B04
8.1.3. RX-CW Test Mode for Base Unit
Set up Base unit in Test mode through USB. (Refer to USB Test Mode (P.43).)
Note:
: Enter key.
: Space key.
(*1) Refer to Check Table for RF part (P.73) for proper Handset settings.
8.1.4. Test Link Mode for Base Unit
"For test link only, No voice."
Set up Base unit in Test mode through USB. (Refer to USB Test Mode (P.43).)
Note:
: Enter key.
: Space key.
(*1) Refer to Test Link Mode for Handset (P.30). If can not proceed to the next step, refer to Registering a handset to the base
unit in the Operating Instructions.
(*2) Refer to Check Table for RF part (P.73) and Test Link Mode for Handset (P.30) for proper Handset settings.
(*3) Refer to Frequency Table (P.93).
Step Test Command Content Description
1
ts
Enter test mode Make sure the Echo back “TEST” after this command.
2
b0
End the BER mode
3
saX
Antenna setting
X = antenna setting
0=Auto select, 1= Antenna 1, 2= Antenna 2
4
pX
TX power setting
X = TX power level
1=Low power, 2=High power
5b4XX RX-CW Mode (*1)
XX = channel setting
00 - 04 (HEX)
6
b0
End the BER mode
7
z
Exit Test Mode
Step Test Command Content Description
1
ts
Enter test mode Make sure the Echo back “TEST” after this command.
2
saX
Antenna setting
X = antenna setting
0=Auto select, 1= Antenna 1, 2= Antenna 2
3
pX
TX power setting
X = TX power level
1=Low power, 2=High power
4
cXX
Channel setting
XX = channel setting (*3)
00 - 04 (HEX)
5
a3e 2
Test link Enable
6
pd
Start dummy bearer Link Standby mode
7 Turn to Test Link Mode (*2)
Set the Handset to "Test Link Mode" (*1) beside the Base Unit, then
the base unit turns to "Test Link Mode" .
8
srX
RX Gain level setting
X = RX gain level
0=High gain, 3=Low gain
9
rsi
Get current RSSI value
10 Exit Test Link Mode Press OFF key of the handset.
11
b0
End the BER mode
12
z
Exit Test Mode