27
KX-TGP500B04/KX-TPA50B04
8.1.5. Adjustment Mode for Base Unit
Set up Base unit in Test mode through USB. (Refer to USB Test Mode (P.43).)
Note:
: Enter key.
: Space key.
Cross Reference
Check and Adjust X501 (Base Unit) Frequency (P.90)
Step Test Command Content Description
1
ts
Enter test mode Make sure the Echo back “TEST” after this command.
2
nc XX
Adjust the BMC_CLK frequency
XX: 00 - 3F (HEX)
Write the adjust value in XCR register.
Repeat this command until BMC_CLK = 13.824MHz.
3
nc
Store the adjust value
If BMC_CLK = 13.824MHz, execute this command to store the adjust
value.
Write the adjust value in FLASH memory.
4
z
Exit Test Mode