8.2. Soft Dry Mode Operation
- The unit starts cooling operation until the room temperature
reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.
- During Soft Dry operation, the Indoor Fan will operate at low speed.
- The operation will be switched on and off for up to 10 minutes
ON and 6 minutes OFF”. Once Soft Dry operation is turned off,
it stops for 6 minutes.
Time Delay Safety Control
- Once the compressor stops, it will not start for 3 minutes during
Cooling operation.
Starting Current Control
- Same as Starting Current Control for Cooling Mode operation.