Cooling or Soft Dry Operation
When you press the SLEEP Mode, the following movement will start to avoid overcooling.
- The fan speed refer to Indoor Fan Motor Control.
- The setting temperature will be risen by 0.5°C at the start of
operation and by 0.C one hour later.
- The operation will stop after 8 hours.
- When using together with the Timer, the ON-Timer has priority.
Heating Operation
When you press the SLEEP Mode, the following movement will start to avoid overheating.
- The fan speed refer to Indoor Fan Motor Control.
- The setting temperature will be decrease by C at the start of
operation and by C one hour later.
- The operation will stop after 8 hours.
- When using together with the Timer, the ON-Timer has priority.
8.6. Random Auto Restart Control
- If there is a power failure, operation will be automatically restarted
after 3 to 5 1/2 minutes when the power is resumed. It will start
with previous operation mode and airflow direction.
- Restart time is decided randomly using 4 parameter:
Intake air temperature, setting temperature, fan speed and Air