Size F 200 V
Use terminal blocks.
Terminal block
No.
(From above)
Main power input
terminal
Control power input
terminal
Regenerative resistor
connecting terminal
Normally, short out the circuit between B and RB.
To use an external regenerative resistor (customer prepared), open between RB
and B and connect an external regenerative resistor between P and B.
In addition, parameter setting is required for the regenerative resistor.
For details, refer to "Technical Reference - Functional Specification ".
Do not connect anything to the N terminal.
Connect each phase of the motor wiring.
U: U phase, V: V phase, W: W phase
Earth terminal for grounding
* Tighten the Earth screw with a torque of m, M5: 1.8 to 2.0 N · m..
* Tighten the terminal block screws with a torque of M5: 1.8 to 2.0 N · m.
* Tighten the fixing for the terminal block cover screws with a torque of M3: 0.19 to 0.21 N · m.
* The screws may be damaged if the tightening torque has exceeded the maximum value.