8/80
2.17. SYSTEM SELECTOR
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 53h 4Ch 03h
Character A D Z Z ; O S L
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 53h 4Ch 03h
Character O S L
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
No No No Yes No Yes Yes Yes
2.18. ASPECT key
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 53h 31h 03h
Character A D Z Z ; V S 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 53h 31h 03h
Character V S 1
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
No No No Yes No Yes Yes Yes
2.19. Numeric key
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 4Eh 4Bh 3Ah *1 03h
Character A D Z Z ; O N K : *2
Parameters (*1, *2)
0 key 1 key 2 key 3 key 4 key 5 key 6 key 7 key 8 key 9 key
Hexadecimal 30h 31h 32h 33h 34h 35h 36h 37h 38h 39h
Character 0 1 2 3 4 5 6 7 8 9
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 4Eh 4Bh 3Ah *1 03h
Character O N K : *2
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
No No No Yes No Yes Yes Yes
2.20. LAMP SELECT
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Ch 50h 4Dh 3Ah *1 03h
Character A D Z Z ; L P M : *2
Parameters (*1, *2)
DUAL SINGLE LAMP1 LAMP2
Hexadecimal 30h 31h 32h 33h
Character 0 1 2 3
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Ch 50h 4Dh 3Ah *1 03h
Character L P M : *2
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
No Ye s No Yes Yes No Yes Yes
Note:
- Calls back ER401 while the lamp has been switched.
2.21. INSTALLATION
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 49h 4Ch 3Ah *1 03h
Character A D Z Z ; O I L : *2
Parameters (*1, *2)
FRONT/FLOOR REAR/FLOOR FRONT/CEILING REAR/CEILING
Hexadecimal 30h 31h 32h 33h
Character 0 1 2 3
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 49h 4Ch 3Ah *1 03h
Character O I L : *2
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
No Ye s No Yes Yes No Yes Yes