2.26. FUNCTION BUTTON
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 46h 43h 3Ah *1 03h
Character A D Z Z ; O F C : *2
Parameters (*1, *2)
DISABLE SYSTEM SELECTOR SYSTEM DAYLIGHT VIEW
Hexadecimal 30h 31h 32h
Character 0 1 2
SUB MEMORY LIST FREEZE SIDE BY SIDE
Hexadecimal 33h 34h 35h
Character 3 4 5
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 46h 43h 3Ah *1 03h
Character O F C : *2
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
No Ye s No Yes Yes Ye s Yes Yes
Note:
- Only for PT-D6000*, the parameter 5 (SIDE BY SIDE) is not available. In this case, ER402 is returned.
2.27. SUB MEMORY CHANGE
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 43h 53h 3Ah
Character A D Z Z ; O C S :
Hexadecimal *1 *3 03h
Character *2 *4
Parameters (*1, *2, *3, *4)
"nn" of the sub memory number (mm-nn)
01 02 03 04
Hexadecimal 30h 31h 30h 32h 30h 33h 30h 34h
Character 0 1 0 2 0 3 0 4
93 94 95 96
Hexadecimal 39h 33h 39h 34h 39h 35h 39h 36h
Character 9 3 9 4 9 5 9 6
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 43h 53h 3Ah *1 *3 03h
Character O C S : *2 *4
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
No No No No Yes No Yes Yes