38/80
2.94. SDI SIGNAL LEVEL
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 45h 44h 3Ah
Character A D Z Z ; O E D :
Hexadecimal 53h 44h 49h 2Dh 4Ch 45h 56h 45h 4Ch *1 03h
Character S D I - L E V E L *2
Parameters (*1, *2)
64-940 4-1019
Hexadecimal 30h 31h
Character 0 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 45h 44h 3Ah 53h 44h 49h
Character O E D : S D I
Hexadecimal 2Dh 4Ch 45h 56h 45h 4Ch *1 03h
Character - L E V E L *2
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
No Ye s No Yes Yes No Yes Yes
2.95. SIDE BY SIDE
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 44h 57h 03h
Character A D Z Z ; O D W
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 44h 57h 30h
Character O D W
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
No No No Yes No No No Yes
Note:
- Starts SIDE BY SIDE mode while SIDE BY SIDE is not activated, and terminates SIDE BY SIDE mode while
SIDE BY SIDE is activated.
2.96. NO SIGNAL SHUT-OFF
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 46h 3Ah
Character A D Z Z ; O A F :
Hexadecimal *1 *3 03h
Character *2 *4
Parameters (*1, *2, *3, *4)
DISABLE 10MIN. 20MIN. 30MIN. 40MIN.
Hexadecimal 30h 30h 31h 30h 32h 30h 33h 30h 34h 30h
Character 0 0 1 0 2 0 3 0 4 0
50MIN. 60MIN. 70MIN. 80MIN. 90MIN.
Hexadecimal 35h 30h 36h 30h 37h 30h 38h 30h 39h 30h
Character 5 0 6 0 7 0 8 0 9 0
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 44h 41h 46h 3Ah *1 03h
Character O A F : *2
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
No Ye s No Yes Yes Ye s Yes Yes