44/80
2.113. Query COLOR
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 43h 03h
Character A D Z Z ; Q V C
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 *3 *5 03h
Character *2 *4 *6
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes No No No Yes Yes Yes Ye s
Parameters (*1, *2, *3, *4, *5, *6)
-31 -30 -29
Hexadecimal 30h 30h 31h 30h 30h 32h 30h 30h 33h
Character 0 0 1 0 0 2 0 0 3
+29 +30 +31
Hexadecimal 30h 36h 31h 30h 36h 32h 30h 36h 33h
Character 0 6 1 0 6 2 0 6 3
2.114. Query TINT
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 54h 03h
Character A D Z Z ; Q V T
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 *3 *5 03h
Character *2 *4 *6
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes No No No Yes Yes Yes Ye s
Parameters (*1, *2, *3, *4, *5, *6)
-31 -30 -29
Hexadecimal 30h 30h 31h 30h 30h 32h 30h 30h 33h
Character 0 0 1 0 0 2 0 0 3
+29 +30 +31
Hexadecimal 30h 36h 31h 30h 36h 32h 30h 36h 33h
Character 0 6 1 0 6 2 0 6 3
2.115. Query COLOR TEMPERATURE
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 54h 45h 03h
Character A D Z Z ; Q T E
Response (Callback)
DEFAULT
Hexadecimal 02h 31h 30h 03h
Character 1 0
USER
Hexadecimal 02h 34h 03h
Character 4
MIDDLE
Hexadecimal 02h 31h 03h
Character 1
HIGH
Hexadecimal 02h 32h 03h
Character 2
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes No No Ye s Yes Yes Yes Yes