2.144. Query BLANKING - LOWER
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 4Ch 42h 03h
Character A D Z Z ; Q L B
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 *3 *5 03h
Character *2 *4 *6
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes No No No Yes Yes Yes Ye s
Parameters (*1, *2, *3, *4, *5, *6)
0 1 2
Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h
Character 0 0 0 0 0 1 0 0 2
PT-D6000*
381 382 383
Hexadecimal 33h 38h 31h 33h 38h 32h 33h 38h 33h
Character 3 8 1 3 8 2 3 8 3
PT-DW6300*
397 398 399
Hexadecimal 33h 39h 37h 33h 39h 38h 33h 39h 39h
Character 3 9 7 3 9 8 3 9 9
PT-DZ6710*/DZ6700*
597 598 599
Hexadecimal 35h 39h 37h 35h 39h 38h 35h 39h 39h
Character 5 9 7 5 9 8 5 9 9
2.145. Query BLANKING - RIGHT
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 4Ch 52h 03h
Character A D Z Z ; Q L R
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 *3 *5 03h
Character *2 *4 *6
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes No No No Yes Yes Yes Ye s
Parameters (*1, *2, *3, *4, *5, *6)
PT-D6000*
509 510 511
Hexadecimal 35h 30h 39h 35h 31h 30h 35h 31h 31h
Character 5 0 9 5 1 0 5 1 1
PT-DW6300*
637 638 639
Hexadecimal 36h 33h 37h 36h 33h 38h 36h 33h 39h
Character 6 3 7 6 3 8 6 3 9
PT-DZ6710*/DZ6700*
957 958 959
Hexadecimal 39h 35h 37h 39h 35h 38h 39h 35h 39h
Character 9 5 7 9 5 8 9 5 9