59/80
2.155. Query GEOMETRY
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 58h 3Ah
Character A D Z Z ; Q V X :
Hexadecimal 47h 4Dh 4Dh 49h 30h 03h
Character G M M I 0
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 47h 4Dh 4Dh 49h 30h 3Dh 2Bh *1 *3
Character G M M I 0 = + *2 *4
Hexadecimal *5 *7 *9 03h
Character *6 *8 *10
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes Ye s No Yes Yes Ye s Yes Ye s
Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10)
OFF KEYSTONE
Hexadecimal 30h 30h 30h 30h 30h 30h 30h 30h 30h 31h
Character 0 0 0 0 0 0 0 0 0 1
CURVED PC
Hexadecimal 30h 30h 30h 30h 32h 30h 30h 30h 30h 33h
Character 0 0 0 0 2 0 0 0 0 3
Note:
- For PT-DZ6700*/DW6300*/D6000*, ER401 is returned.
2.156. Query GEOMETRY:KEYSTONE - VERTICAL KEYSTONE
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 58h 3Ah
Character A D Z Z ; Q V X :
Hexadecimal 47h 4Dh 4Bh 49h 31h 03h
Character G M K I 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 47h 4Dh 4Bh 49h 31h 3Dh *1 *3 *5
Character G M K I 1 = *2 *4 *6
Hexadecimal *7 *9 *11 03h
Character *8 *10 *12
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes Ye s No Yes Yes Ye s Yes Ye s
Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10, *11, *12)
-127 -126
Hexadecimal 2Dh 30h 30h 31h 32h 37h 2Dh 30h 30h 31h 32h 36h
Character - 0 0 1 2 7 - 0 0 1 2 6
126 127
Hexadecimal 2Bh 30h 30h 31h 32h 36h 2Bh 30h 30h 31h 32h 37h
Character + 0 0 1 2 6 + 0 0 1 2 7
Note:
- For PT-DZ6700*/DW6300*/D6000*, ER401 is returned.