68/80
2.175. Query LAMP2 RUNTIME
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 24h 4Ch 3Ah
Character A D Z Z ; Q $ L :
Hexadecimal 32h 03h
Character 2
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 *3 *5 *7 03h
Character *2 *4 *6 *8
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes Ye s Yes Yes Ye s Yes Yes Yes
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)
When the lamp is Normal type:
Answered time = (Lamp runtime in HIGH power)+((Lamp runtime in LOW power)×3÷4)
When the lamp is Long-life type:
Answered time = Lamp runtime
0 h 1 h
Hexadecimal 30h 30h 30h 30h 30h 30h 30h 31h
Character 0 0 0 0 0 0 0 1
9998 h 9999 h
Hexadecimal 39h 39h 39h 38h 39h 39h 39h 39h
Character 9 9 9 8 9 9 9 9
2.176. Query LAMP SELECT
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 53h 4Ch 03h
Character A D Z Z ; Q S L
Response (Callback)
DUAL
Hexadecimal 02h 30h 03h
Character 0
SINGLE
Hexadecimal 02h 31h 03h
Character 1
LAMP1
Hexadecimal 02h 31h 03h
Character 2
LAMP2
Hexadecimal 02h 33h 03h
Character 3
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes Ye s Yes Yes Ye s Yes Yes Yes
2.177. Query Lamp Status
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 24h 53h 03h
Character A D Z Z ; Q $ S
Response (Callback)
Lamp OFF
Hexadecimal 02h 30h 03h
Character 0
In turning ON
Hexadecimal 02h 31h 03h
Character 1
Lamp ON
Hexadecimal 02h 32h 03h
Character 2
In turning OFF (Cooling)
Hexadecimal 02h 33h 03h
Character 3
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes Ye s Yes Yes Ye s Yes Yes Yes