71/80
2.185. Query Time
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 47h 54h 03h
Character A D Z Z ; Q G T
Response (Callback)
Hexadecimal 02h *h1 *h2 *m1 *m2 *s1 *s2 03h
Character
Parameters
*h1, *h2: Hour (2 digits)
*m1, *m2: Minute (2 digits)
*s1, *s2: Second (2 digits)
Set it by UTC (Coordinated Universal Time).
Example: 3 seconds at 3:45 p.m.
*h1 *h2 *m1 *m2 *s1 *s2
Hexadecimal 31h 35h 34h 35h 30h 33h
Character 1 5 4 5 0 3
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes Ye s No Yes Yes Ye s Yes Ye s
2.186. Query Model (Series) Name
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 49h 44h 03h
Character A D Z Z ; Q I D
Response (Callback)
In the period when the command can be accepted
PT-D6000*
Hexadecimal 02h 44h 36h 30h 30h 30h 03h
Character D 6 0 0 0
PT-DW6300*
Hexadecimal 02h 44h 57h 36h 33h 30h 30h 03h
Character D W 6 3 0 0
PT-DZ6700*
Hexadecimal 02h 44h 5Ah 36h 37h 30h 30h 03h
Character D Z 6 7 0 0
PT-DZ6710*
Hexadecimal 02h 44h 5Ah 36h 37h 31h 30h 03h
Character D Z 6 7 1 0
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes Ye s Yes Yes Ye s Yes Yes Yes
2.187. Query Lamp ON Status
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 4Ch 53h 03h
Character A D Z Z ; Q L S
Response (Callback)
Lamp 1 OFF, Lamp 2 OFF
Hexadecimal 02h 30h 03h
Character 0
Lamp 1 ON, Lamp 2 OFF
Hexadecimal 02h 31h 03h
Character 1
Lamp 1 OFF, Lamp 2 ON
Hexadecimal 02h 32h 03h
Character 2
Lamp 1 ON, Lamp 2 ON
Hexadecimal 02h 33h 03h
Character 3
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes Ye s Yes Yes Ye s Yes Yes Yes