1-5
1
Single-Type
1-1. Unit Specifi cations
4-Way Cassette Type S-125PU1R5 / U-125PE1R5
INDOOR MODEL
S–125PU1R5
PANEL MODEL
CZ–KPU2
OUTDOOR MODEL
U–125PE1R5
Branch pipe MODEL
–
PERFORMANCE TEST CONDITION
ISO5151 / AS/NZS3823
POWER SUPPLY
ø, Hz
1ø 50 Hz 1ø 50 Hz
V
230 V 240 V 230 V 240 V Min Max
C
O
O
L
I
N
G
CAPACITY
kW
12.5 12.5 3.3 14.0
BTU/h
42700 42700 11300 47800
CURRENT A
0.76 0.73 15.3 14.8 – –
INPUT POWER
W
100 100 3.370 k 3.370 k – –
TOTAL W
– 3.470 k 3.470 k 840 4.600 k
ANNUAL CONSUMPTION TOTAL W *
4
– 1735 – – –
EER/AEER /STR RAT TOTAL (W/W)
––
3.60/3.56/2.0
3.60 3.93 3.04
POWER FACTOR %
– – 96 95 – –
NOISE INDOOR
(H/M/L)
dB–A
45/39/33
Power Level dB
63/56/50
NOISE OUTDOOR
(H/L)
dB–A
53/–
Power Level dB
70/–
H
E
A
T
I
N
G
CAPACITY
kW
14.0 14.0 4.1 16.0
BTU/h
47800 47800 14000 54600
CURRENT A
0.73 0.73 15.4 14.9 – –
INPUT POWER
W
100 100 3.400 k 3.400 k – –
TOTAL W
– 3.500 k 3.500 k 900 5.200 k
COP/ACOP /STR RAT TOTAL (W/W)
––
4.00/3.95/3.0
4.00 4.56 3.08
POWER FACTOR %
– – 96 95 – –
NOISE INDOOR
(H/M/L)
dB–A
45/39/33 – / /
Power Level dB
63/56/50 –
NOISE OUTDOOR
(H/L)
dB–A
– 53/– / /
Power Level dB
– 70/–
EXTRA LOW TEMP
TOTAL CAPACITY(kW)/INPUT POWER(W)/COP
–
MAX CURRENT(A)/MAX INPUT POWER(W)
– 0.76/100 0.73/100 –
28.0/6.200 k 28.0/6.400 k
/
STARTING CURRENT(A)/COMP OUTPUT(W)
––––
15.7/3.0 K 15.2/3.0 K
/
NETWORK IMPEDANCE(ΩMAX.)
––
FM OUTPUT (W)
90 90 × 2 /
MOISTURE REMOVAL VOLUME L/h(Pt/h)
7.9 (16.6) –
Extarnal static pressure
Pa (mmAq)
–
I/D AIR
FLOW
COOL m
3
/min (ft
3
/min)
35 (1236)
HEAT m
3
/min (ft
3
/min)
35 (1236)
O/D AIR
FLOW
COOL m
3
/min (ft
3
/min)
130 (4591)
HEAT m
3
/min (ft
3
/min)
110 (3885)
REFRIGERANT TYPE, AMOUNT g(oz)
R410A 3.40 k (119.9) /
P
R
O
D
I
M
HEIGHT
:
H mm (inch)
319 (12–9/16) 1416 (55–3/4) /
WIDTH
:
W mm (inch)
840 (33–3/32) 940 (37–1/32) /
DEPTH
:
D mm (inch)
840 (33–3/32) 340 (13–13/32) /
P
A
C
D
I
M
HEIGHT
:
H mm
361 1556 /
WIDTH
:
W mm
929 1055 /
DEPTH
:
D mm
929 485 /
MASS
(NET) kg(lb)
27(60) 98(216) /
(GROSS) kg(lb)
33(73) 108(238) /
LAYERS LIMIT (actually)
11(12) 1(2)
Operation
Condition
Cool (DBT) 18˚C – 32˚C -15˚C – 46˚C
Heat (DBT) 16˚C – 30˚C -20˚C – 24˚C
P
I
P
I
N
G
PIPE DIAMETER mm (inch)
(Liquid)
ø
9.52(3/8) (Gas)
ø
15.88(5/8) (Liquid)
ø
9.52(3/8) (Gas)
ø
15.88(5/8)
CONNECT METHOD, STD LENGTH m (ft)
fl ared type, 5.0(16.4) fl ared type, 5.0(16.4)
PIPE LENGTH RANGE m (ft)
5 – 75 (16.4 – 246.1) – –
I/D&O/D HEIGHT DIRRERENCE m (ft)
15 (OD located lower)/30 (OD located higher) (49.2/98.4)
ADD GAS AMOUNT g/m (oz/ft)
50 (537.6)
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
30 (98.4)
*1
:
In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2
:
If the EUROVENT Certifi ed models can be operated under the “extra-low” temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3
:
Network Impedance shall be applicable for EUROPE and CHINA models.
*4
:
The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5
:
EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
Sec1.indb5Sec1.indb5 2012/03/0717:29:552012/03/0717:29:55