7.3. Display Content
No. Abnormal Items Error
Display
Method of detection
1 CLOSE SW abnormal H16 Detect error during closing operation and memorised
it
as an error.
2 REST SW abnormal F15 Under normal operation (Self-Diagnostic Mode
inclusive),
this error occurs when the REST SW ON is not
detected
within the specified time (5000 ms) and shall be
memorised.
3 Transmission error between
CD servo LSI and micon
F26 Under normal operation (Self-Diagnostic Mode
inclusive),
this error occurs when the selection is set to CD and
SENSE =H’ is detected and SENSE =L’ is not detected
within a fail-safe time (20 ms) after system command
transmission was sent.
8. Disassembly and Main Component Replacement
Procedures
ATTENTION SERVICER”
Some chassis components maybe have sharp edges. Be careful when
diassembling and servicing.