● Combination of Multiple Unit
2. Heating Capacity Performance Data
4-Way Cassette 60×60 Type
1-12. Capacity Table
unit : kW
Model
Power
Source
Ambient
Return
Air
DB TC IPT TC IPT TC IPT TC IPT TC IPT
16 7.3 2.13 7.5 2.15 8.6 2.12 8.8 1.98 8.8 1.83
20 7.0 2.20 7.2 2.21 8.0 2.15 8.0 2.01 8.0 1.85
24 6.6 2.26 6.8 2.28 7.2 2.19 7.2 2.06 7.2 1.89
16 11.6 3.21 11.6 3.06 11.6 2.81 11.6 2.61 11.6 2.07
20 11.2 3.33 11.2 3.18 11.2 2.93 11.2 2.72 11.1 2.18
24 10.7 3.45 10.7 3.30 10.8 3.05 10.8 2.84 10.7 2.30
16 11.6 3.21 11.6 3.06 11.6 2.81 11.6 2.61 11.6 2.07
20 11.2 3.33 11.2 3.18 11.2 2.93 11.2 2.72 11.1 2.18
24 10.7 3.45 10.7 3.30 10.8 3.05 10.8 2.84 10.7 2.30
16 13.9 4.00 14.4 3.88 14.6 3.74 14.6 3.41 14.5 2.66
20 13.3 4.16 13.9 4.04 14.0 3.90 14.0 3.56 13.9 2.81
24 12.8 4.31 13.3 4.20 13.4 4.06 13.4 3.72 13.4 2.97
16 13.9 3.99 14.4 3.87 14.6 3.73 14.6 3.40 14.5 2.65
20 13.3 4.15 13.9 4.03 14.0 3.89 14.0 3.56 13.9 2.80
24 12.8 4.30 13.3 4.19 13.4 4.05 13.4 3.71 13.4 2.96
16 16.7 4.73 16.7 4.71 16.6 4.63 16.6 4.02 16.6 3.32
20 16.0 4.92 16.0 4.91 16.0 4.82 16.0 4.22 15.9 3.51
24 15.4 5.11 15.4 5.10 15.4 5.01 15.4 4.41 15.3 3.71
230V
240V
50Hz
1phase
(3 phase)
S-50PY1E5×2
U-100PE1E5
(U-100PE1E8)
15
㷄
Outdoor air intake temp (
㷄
ޓW.B.㧕
-5
㷄
0
㷄
6
㷄
10
㷄
S-50PY1E5×3
U-140PE1E5
(U-140PE1E8)
230V
240V
50Hz
1phase
(3 phase)
230V
240V
50Hz
1phase
(3 phase)
S-45PY1E5×3
U-125PE1E5
(U-125PE1E8)
230V
240V
50Hz
1phase
(3 phase)
S-36PY1E5×2
U-71PE1E5
230V
240V
50Hz
1phase
S-36PY1E5×3
U-100PE1E5
(U-100PE1E8)
230V
240V
50Hz
1phase
(3 phase)
S-36PY1E5×4
U-125PE1E5
(U-125PE1E8)
TC :Cooling Capacity
IPT :Cooling Power Consumption