7. Press PLAY/TUNE/TIME ADJ UP (After TPS function, tape will
stop automatically)
8. Press REC/STOP (Tape will not move)
9. Press STOP/TUNE MODE to indicate Error code.
- If several problem exist, error code will change each time
when /TUNE MODE is pressed.
(e.g. H01 H03 F01 .....etc.)
10. Press TAPE, DECK 1/2 to select Deck 1.
11. Repeat step 2 to 9 to test Deck 1. (Tape Deck 1 will not check H02
because of no recording function)
9.4. CD Mechanism Test (F15, F26, F16, F17, F27, F28, F29, H15)
1. Press CD”.
2. Press OPEN/CLOSE (1) and place a CD.
3. Press OPEN/CLOSE (1) to close the tray.
4. Press OPEN/CLOSE (5) and wait until the tray is open.
5. Press OPEN/CLOSE (1) and remove the CD.
6. Press OPEN/CLOSE (1) to close the tray.
7. Press /TUNE MODE to indicate Error Code.
- If several problem exist, error code will change each time
when /TUNE MODE is pressed. (e.g. F15 F26 F16 ....
etc).
9.5. To clear all Error code
1. Press STOP/TUNE MODE button for 5 seconds.
2. FL indicator shows CLEAR for 1 second and change to T”.
9.6. How to get out from Self-Diagnostic function
1. Press Power button OFF.
9.7. Power Amplifier Failure (F61)
1. When power amplifier fail, F61 will indicate automatically.