7. Press “PLAY/TUNE/TIME ADJ UP” (After TPS function, tape will
stop automatically)
8. Press “REC/STOP” (Tape will not move)
9. Press “STOP/TUNE MODE” to indicate Error code.
- If several problem exist, error code will change each time
when “ /TUNE MODE” is pressed.
(e.g. H01 H03 F01 .....etc.)
10. Press “TAPE, DECK 1/2” to select Deck 1.
11. Repeat step 2 to 9 to test Deck 1. (Tape Deck 1 will not check H02
because of no recording function)
9.4. CD Mechanism Test (F15, F26, F16, F17, F27, F28, F29, H15)
1. Press “CD”.
2. Press “OPEN/CLOSE (1)” and place a CD.
3. Press “OPEN/CLOSE (1)” to close the tray.
4. Press “OPEN/CLOSE (5)” and wait until the tray is open.
5. Press “OPEN/CLOSE (1)” and remove the CD.
6. Press “OPEN/CLOSE (1)” to close the tray.
7. Press “ /TUNE MODE” to indicate Error Code.
- If several problem exist, error code will change each time
when “ /TUNE MODE” is pressed. (e.g. F15 F26 F16 ....
etc).
9.5. To clear all Error code
1. Press “STOP/TUNE MODE” button for 5 seconds.
2. FL indicator shows “CLEAR” for 1 second and change to “T”.
9.6. How to get out from Self-Diagnostic function
1. Press “Power” button OFF.
9.7. Power Amplifier Failure (F61)
1. When power amplifier fail, F61 will indicate automatically.